Home :: Technical Resources :: Material Safety Data Sheet :: Part 1
|
MATERIAL SAFETY DATA SHEET
PART 1: What is the material and what do I need to know about it?
|
|
|
|
1. PRODUCT IDENTIFICATION
|
|
TRADE NAME AS LABELED:
|
DMG DIVERSITY NAVIGATOR™ - EXONIC
AMPLIFICATION AND SEQUENCING SYSTEM
|
|
PART NUMBER:
|
DMG-1A1-200, DMG-1A2-200, DMG-2A6-200,
DMG-2B6-200, DMG-2C8-200, DMG-2C9-200,
DMG-2C19-200, DMG-2D6-200, DMG-2E1-200,
DMG-3A4-200, DMG-3A5-200, DMG-POR-200
|
|
MANUFACTURER:
|
BioVentures, Inc.
|
|
ADDRESS:
|
P.O. BOX NUMBER 2561
MURFREESBORO, TN 37133-2561
|
|
EMERGENCY PHONE:
|
615 896-7353
|
|
DATE OF PREPARATION:
|
JUNE 18, 2003
|
|
|
2. COMPOSITION AND INFORMATION ON INGREDIENTS
|
|
Component 1: Amplification primer pairs, nested primer pairs and sequencing primers
|
|
Chemical Name
|
CAS#
|
%v/v
|
Exposure Limits In Air
|
|
ACGIH
|
OSHA
|
OTHER
|
|
TLV mg/m3
|
STEL mg/m3
|
PEL mg/m3
|
STEL mg/m3
|
IDLH mg/m3
|
| Hydroxymethyl-aminomethane (Tris) |
78-86-1 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Ethylenediamine-tetra-acetic acid (EDTA) |
60-00-4 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Acetonitrile |
75-05-8 |
2 |
NE |
NE |
NE |
NE |
NE |
NE |
| Synthetic oligonucleotides |
NA |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Water |
7732-18-5 |
Balance |
NE |
NE |
NE |
NE |
NE |
NE |
NE = Not Established, NA = Not Applicable
*All WHMIS required information is included in the appropriate sections based on ANSI Z400.1-1993 format
|
|
|
Component 2: DNA control sample
|
|
Chemical Name
|
CAS#
|
%v/v
|
Exposure Limits In Air
|
|
ACGIH
|
OSHA
|
OTHER
|
|
TLV mg/m3
|
STEL mg/m3
|
PEL mg/m3
|
STEL mg/m3
|
IDLH mg/m3
|
| Human genomic DNA |
NA |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Hydroxymethyl-aminomethane (Tris) |
78-86-1 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Ethylenediamine-tetra- acetic acid(EDTA) |
60-00-4 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Polyoxyethylene sorbitate monolaurate (Tween-20) |
9005-64-5 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Water |
7732-18-5 |
Balance |
NE |
NE |
NE |
NE |
NE |
NE |
|
NE = Not Established, NA = Not Applicable
|
|
|
Component 3: 5X PCR Buffer
|
|
Chemical Name
|
CAS#
|
%v/v
|
Exposure Limits In Air
|
|
ACGIH
|
OSHA
|
OTHER
|
|
TLV mg/m3
|
STEL mg/m3
|
PEL mg/m3
|
STEL mg/m3
|
IDLH mg/m3
|
| Hydroxymethyl-Aminomethane (Tris) |
78-86-1 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Potassium Chloride |
7447-40-7 |
<2 |
NE |
NE |
NE |
NE |
NE |
NE |
| Magnesium Chloride |
7791-18-6 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Dimethyl Sulf- oxide (DMSO) |
67-68-5 |
10 |
NE |
NE |
NE |
NE |
NE |
NE |
| DL-Dithiothreitol (DTT) |
3483-12-3 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Deoxyadenosine-5’-triphosphate |
1927-31-7 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Deoxycytidine-5’-triphosphate |
102783-51-7 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Deoxyguanasine-5’-triphosphate |
93919-41-6 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Deoxythymidine-5’-triphosphate |
18423-43-3 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Water |
7732-18-5 |
Balance |
NE |
NE |
NE |
NE |
NE |
NE |
|
NE = Not Established, NA = Not Applicable
|
|
|
Component 4: 5X Sequencing Buffer
|
|
Chemical Name
|
CAS#
|
%v/v
|
Exposure Limits In Air
|
|
ACGIH
|
OSHA
|
OTHER
|
|
TLV mg/m3
|
STEL mg/m3
|
PEL mg/m3
|
STEL mg/m3
|
IDLH mg/m3
|
| Hydroxymethyl-aminomethane (Tris) |
78-86-1 |
<4 |
NE |
NE |
NE |
NE |
NE |
NE |
| Magnesium Chloride |
7791-18-6 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Water |
7732-18-5 |
Balance |
NE |
NE |
NE |
NE |
NE |
NE |
|
NE = Not Established, NA = Not Applicable
|
|
|
Component 5: BioMarker Extended DNA Marker
|
|
Chemical Name
|
CAS#
|
%v/v
|
Exposure Limits In Air
|
|
ACGIH
|
OSHA
|
OTHER
|
|
TLV mg/m3
|
STEL mg/m3
|
PEL mg/m3
|
STEL mg/m3
|
IDLH mg/m3
|
| Synthetic ds DNA |
NA |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Hydroxymethyl-aminomethane (Tris) |
78-86-1 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Ethylenediamine-tetra- acetic acid(EDTA) |
60-00-4 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Potassium Chloride |
7447-40-7 |
<2 |
NE |
NE |
NE |
NE |
NE |
NE |
| Sodium Azide |
26628-22-8 |
.01 |
NE |
NE |
NE |
NE |
NE |
NE |
| Water |
7732-18-5 |
Balance |
NE |
NE |
NE |
NE |
NE |
NE |
|
NE = Not Established, NA = Not Applicable
|
|
|
Component 6: BioTracker 6X Loading Dye
|
|
Chemical Name
|
CAS#
|
%v/v
|
Exposure Limits In Air
|
|
ACGIH
|
OSHA
|
OTHER
|
|
TLV mg/m3
|
STEL mg/m3
|
PEL mg/m3
|
STEL mg/m3
|
IDLH mg/m3
|
| Glycerol |
56-81-5 |
30 |
NE |
NE |
NE |
NE |
NE |
NE |
| Bromophenol Blue(BPB) |
115-39-9 |
.25 |
NE |
NE |
NE |
NE |
NE |
NE |
| Lauryl Sulfate(SDS) |
151-21-3 |
.75 |
NE |
NE |
NE |
NE |
NE |
NE |
| Hydroxymethyl-aminomethane (Tris) |
78-86-1 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Ethylenediamine-tetra- acetic acid(EDTA) |
60-00-4 |
<1 |
NE |
NE |
NE |
NE |
NE |
NE |
| Water |
7732-18-5 |
Balance |
NE |
NE |
NE |
NE |
NE |
NE |
|
NE = Not Established, NA = Not Applicable
|
|
|
3. HAZARD IDENTIFICATION
|
|
EMERGENCY OVERVIEW
|
|
This product contains nineteen components which are clear, colorless solutions. The primary hazard associated with these solutions is irritation of contaminated eyes and skin or the generation of irritating vapors when solutions are heated. In the event of fire, this product will not contribute significant additional hazards.
|
|
SYMPTOMS OF OVER-EXPOSURE BY ROUTE OF EXPOSURE:
|
|
No adverse health effects should occur from routine use of this material in the manner specified by the manufacturer’s instructions. The only likely symptom of exposure would be reddening or inflammation after accidental injection. The potential health effects of the individual components are as described below:
|
|
THE FOLLOWING INFORMATION DESCRIBES THE EXPECTED HEALTH HAZARDS ASSOCIATED WITH THE COMPONENT SOLUTIONS:
|
|
BIOHAZARD
|
The donors for the DNA control sample were tested for
infectious agents and found to be negative. No testing methods, however, can
offer complete assurance of the absence of infectious agents. Products of human
origin, therefore, should be handled in a manner consistent with the possibility
that an infectious agent may be present.
|
|
INHALATION
|
Inhalation of a vapor, mists, or dusts of this product may cause mild irritation. Symptoms are generally alleviated upon breathing fresh air.
|
|
CONTACT WITH SKIN or EYES
|
Contact with the skin or eyes may cause
mild irritation, which is alleviated upon rinsing.
|
|
SKIN ABSORPTION
|
Avoid contact with Dimethyl Sulfoxide solutions
containing toxic substances with unknown toxicological properties. Dimethyl Sulfoxide is readily absorbed through the skin and may carry such substances into the body.
|
|
INGESTION
|
Ingestion of the product’s components may cause gastric distress.
|
|
INJECTION
|
Injection of the product’s components may cause local reddening, tissue swelling, and discomfort.
|
HEALTH EFFECTS OR RISKS FROM EXPOSURE: An Explanation in Lay Terms. These solutions are not known to cause significant acute or chronic health effects.
|
|
Acute
|
Beyond mild irritation of the skin or eyes, contact with this product does not usually cause acute health effects.
|
|
Chronic
|
This product is not known to cause any significant chronic health effects.
|
|
Continue To Part 2
|